1,286 research outputs found

    Image Denoising using Attention-Residual Convolutional Neural Networks

    Full text link
    During the image acquisition process, noise is usually added to the data mainly due to physical limitations of the acquisition sensor, and also regarding imprecisions during the data transmission and manipulation. In that sense, the resultant image needs to be processed to attenuate its noise without losing details. Non-learning-based strategies such as filter-based and noise prior modeling have been adopted to solve the image denoising problem. Nowadays, learning-based denoising techniques showed to be much more effective and flexible approaches, such as Residual Convolutional Neural Networks. Here, we propose a new learning-based non-blind denoising technique named Attention Residual Convolutional Neural Network (ARCNN), and its extension to blind denoising named Flexible Attention Residual Convolutional Neural Network (FARCNN). The proposed methods try to learn the underlying noise expectation using an Attention-Residual mechanism. Experiments on public datasets corrupted by different levels of Gaussian and Poisson noise support the effectiveness of the proposed approaches against some state-of-the-art image denoising methods. ARCNN achieved an overall average PSNR results of around 0.44dB and 0.96dB for Gaussian and Poisson denoising, respectively FARCNN presented very consistent results, even with slightly worsen performance compared to ARCNN.Comment: Published in: 2020 33rd SIBGRAPI Conference on Graphics, Patterns and Images (SIBGRAPI

    Counting Majorana zero modes in superconductors

    Full text link
    A counting formula for computing the number of (Majorana) zero modes bound to topological point defects is evaluated in a gradient expansion for systems with charge-conjugation symmetry. This semi-classical counting of zero modes is applied to some examples that include graphene and a chiral p-wave superconductor in two-dimensional space. In all cases, we explicitly relate the counting of zero modes to Chern numbers.Comment: 21 pages, 3 figure

    Calibration of low-level laser therapy equipment

    Get PDF
    CONTEXTUALIZAÇÃO: A laserterapia de baixa intensidade (LBI) vem sendo cada vez mais utilizada, porém ainda não há consenso na literatura quanto ao tempo em que os equipamentos devem ser submetidos à aferição ou calibragem. OBJETIVO: Analisar a potência média real (PmR) dos equipamentos de LBI na região da Grande São Paulo. MÉTODOS: Para análise dos equipamentos, utilizou-se um potenciômetro (Lasercheck), próprio para aferição de equipamentos contínuos, o qual foi programado com dados referentes ao comprimento de onda do laser a ser avaliado, obtendo-se assim a PmR emitida. Os equipamentos foram analisados de duas formas: uma, com o LBI desaquecido, e outra, após 10 minutos de uso (aquecido), sendo que três análises foram feitas para cada condição. A caneta emissora foi acoplada ao potenciômetro, o qual fornecia a PmR emitida pelo LBI. Todos os dados e informações referentes à aplicação do laser foram coletados por um questionário respondido pelos responsáveis. RESULTADOS: Os 60 equipamentos avaliados mostraram déficit na PmR com os equipamentos desaquecidos e aquecidos. A análise estatística (ANOVA) mostrou diminuição significativa (P<0,05) da PmR aferida em relação à potência média do fabricante (PmF). Em média, a dose mais empregada nas clínicas foi de 4 J/cm², tendo os efeitos de cicatrização e anti-inflamatório como os mais desejados. Segundo a World Association for Laser Therapy (WALT), para atingir esse efeito, necessita-se de 1 a 4 J de energia final, sendo que apenas um dos 60 aparelhos conseguiria atingir a janela terapêutica preconizada. CONCLUSÃO: Os equipamentos de LBI apresentam um déficit acentuado na PmR, o que mostra uma desordem na utilização desse recurso. Neste estudo, observou-se a necessidade de aferição periódica dos aparelhos de LBI bem como melhor conhecimento técnico dos profissionais envolvidos.BACKGROUND: Despite the increase in the use of low-level laser therapy (LLLT), there is still a lack of consensus in the literature regarding how often the equipment must be calibrated. OBJECTIVE: To evaluate the real average power of LLLT devices in the Greater São Paulo area. METHODS: For the evaluation, a LaserCheck power meter designed to calibrate continuous equipment was used. The power meter was programmed with data related to the laser's wavelength to gauge the real average power being emitted. The LLLT devices were evaluated in two ways: first with the device cooled down and then with the device warmed up for 10 minutes. For each condition, three tests were performed. The laser probe was aligned with the power meter, which provided the real average power being emitted by the LLLT device. All of the data and information related to the laser application were collected with the use of a questionnaire filled in by the supervising therapists. RESULTS: The 60 devices evaluated showed deficit in real average power in the cooled-down and warmed-up condition. The statistical analysis (ANOVA) showed a significant decrease (p<0.05) in the real average power measured in relation to the manufacturer's average power. On average, the most common dose in the clinics was 4 J/cm², and the most desired effects were healing and anti-inflammatory effects. According to the World Association for Laser Therapy (WALT), 1 to 4 J of final energy are necessary to achieve these effects, however only one device was able to reach the recommended therapeutic window. CONCLUSION: The LLLT devices showed a deficit in real average power that emphasized a lack of order in the application of this tool. The present study also showed the need for periodical calibration of LLLT equipment and a better technical knowledge of the therapists involved

    Motivation for Brazilian Older Adult Women to Join a Community Physical Activity Program Before COVID-19 Pandemic

    Full text link
    Background: Intrinsic and extrinsic motivational factors can affect the levels of adherence of physical activity (PA) during the aging process. Objectives: Investigate the intrinsic and extrinsic aspects and motivation that led older women to enroll in and adhere to a community PA program before the COVID-19 pandemic. Methods: Data were collected via transversal survey before the COVID-19 pandemic. The sample consisted of 21 women, participants of a PA workshop, aged between 60 to 86 years [< 1-year (n = 8) and ≥ 1-year (n = 13) groups]. Motivation was assessed by the Motivation Inventory for Regular Physical Activity Practice (IMPRAF-54), using the 60th percentile to categorize high and low motivation, and two open questions. For qualitative assessment, content analysis was used and the answers were framed into subcategories regarding the motivation factors for adherence and permanence. Results: That adherence to the program was motivated by sociability purposes [total score: 36.0 (6.0), median (interquartile range)] and pleasure [34.0; (6.0)], while the main motivation for permanence was health [40.0 (11.0)]. Differences were noticed between the groups for sociability [38.0 (3.0) P = 0.030] and competitiveness [9.50 (12.0); P = 0.037] highest medians for the < 1 year group. Furthermore, the factors that least motivated older women were competitiveness and aesthetics. Conclusions: Health and sociability were the main motivators for the practice of physical activity among older adult women. Motivation played a fundamental role in the permanence of older adult women in the physical activity program
    corecore